<?xml version="1.0" encoding="ISO-8859-1"?><article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance">
<front>
<journal-meta>
<journal-id>1683-9803</journal-id>
<journal-title><![CDATA[Pediatría (Asunción)]]></journal-title>
<abbrev-journal-title><![CDATA[Pediatr. (Asunción)]]></abbrev-journal-title>
<issn>1683-9803</issn>
<publisher>
<publisher-name><![CDATA[Sociedad Paraguaya de Pediatría]]></publisher-name>
</publisher>
</journal-meta>
<article-meta>
<article-id>S1683-98032010000100008</article-id>
<title-group>
<article-title xml:lang="es"><![CDATA[Ventilación de Alta Frecuencia en Recién Nacidos. Un soporte necesario en la Unidades Neonatales]]></article-title>
<article-title xml:lang="en"><![CDATA[High-Frequency Ventilation in Newborns. A Needed Capability in Neonatal Units]]></article-title>
</title-group>
<contrib-group>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Mir Villamayor]]></surname>
<given-names><![CDATA[Ramón]]></given-names>
</name>
<xref ref-type="aff" rid="A01"/>
</contrib>
</contrib-group>
<aff id="A01">
<institution><![CDATA[,Centro Materno Infantil Unidad Cuidados Intensivos Neonatales Jefe de Sala]]></institution>
<addr-line><![CDATA[ ]]></addr-line>
</aff>
<pub-date pub-type="pub">
<day>00</day>
<month>04</month>
<year>2010</year>
</pub-date>
<pub-date pub-type="epub">
<day>00</day>
<month>04</month>
<year>2010</year>
</pub-date>
<volume>37</volume>
<numero>1</numero>
<fpage>52</fpage>
<lpage>56</lpage>
<copyright-statement/>
<copyright-year/>
<self-uri xlink:href="http://scielo.iics.una.py/scielo.php?script=sci_arttext&amp;pid=S1683-98032010000100008&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://scielo.iics.una.py/scielo.php?script=sci_abstract&amp;pid=S1683-98032010000100008&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://scielo.iics.una.py/scielo.php?script=sci_pdf&amp;pid=S1683-98032010000100008&amp;lng=en&amp;nrm=iso"></self-uri><abstract abstract-type="short" xml:lang="es"><p><![CDATA[La ventilación de alta frecuencia es una forma de ventilación mecánica que se utiliza en el recién nacido con insuficiencia respiratoria aguda; se caracteriza por la utilización de pequeños volúmenes corrientes, menor que el espacio muerto anatómico, con frecuencia de ventilación extremadamente alta. Su mecanismo de acción es diferente al de la ventilación convencional, por lo cual es importante conocer sus características técnicas y operacionales antes de su uso clínico. Las ventajas potenciales de esta técnica sobre la ventilación mecánica convencional incluyen su capacidad para realizar un adecuado intercambio gaseoso, en un pulmón lesionado por barotrauma y volutrauma, usando presiones bajas en las vías áreas proximales. En este artículo se presentan algunos tipos de ventilación de alta frecuencia, sobre todo la Ventilación de Alta Frecuencia Oscilatoria, los posibles mecanismos de intercambio gaseoso que realiza este tipo de ventilación, sus principales indicaciones y las estrategias de manejo clínico.]]></p></abstract>
<abstract abstract-type="short" xml:lang="en"><p><![CDATA[High-frequency ventilation is a form of mechanical ventilation used in newborns with acute respiratory insufficiency and is characterized by the use of small volumes of flow, smaller than the anatomic space available, but at extremely high frequency. Its mechanism of action is different from that of conventional ventilation, for which reason it is important to recognize its technical and operational characteristics prior to clinical use. The advantages of this technique over conventional mechanical ventilation include the ability to achieve adequate gas exchange in a lung damaged by barotrauma or volutrauma by using low pressures in the proximal airways. In this article we present some types of high-frequency ventilation, concentrating on high frequency oscillatory ventilation, the possible mechanisms of gas exchange occurring in this type of ventilation, its primary indications, and some strategies for clinical management.]]></p></abstract>
<kwd-group>
<kwd lng="es"><![CDATA[Ventilación de Alta frecuencia]]></kwd>
<kwd lng="es"><![CDATA[recién nacido]]></kwd>
<kwd lng="es"><![CDATA[insuficiencia respiratoria]]></kwd>
<kwd lng="en"><![CDATA[High-frequency ventilation]]></kwd>
<kwd lng="en"><![CDATA[newborns]]></kwd>
<kwd lng="en"><![CDATA[respiratory insufficiency]]></kwd>
</kwd-group>
</article-meta>
</front><body><![CDATA[ <p align="right"><font size="3" face="Verdana"><b>ART&Iacute;CULO ESPECIAL</b></font></p>     <p align="left">&nbsp;</p>     <p align="left"><font size="4" face="Verdana"><b>Ventilaci&oacute;n de Alta Frecuencia en Reci&eacute;n Nacidos. Un soporte necesario en la Unidades Neonatales</b></font></p>      <p align="left"><font size="3" face="Verdana"><b>High-Frequency Ventilation in Newborns. A Needed Capability in Neonatal Units</b></font></p>      <p align="left">&nbsp;</p>     <p align="left"><font size="2" face="Verdana"><b>Prof. Dr. Ram&oacute;n Mir Villamayor (1).</b></font></p>       <p align="left"><font size="2" face="Verdana">1. Pediatra-Neonat&oacute;logo. Jefe de Sala. Unidad Cuidados Intensivos Neonatales. Centro Materno Infantil y Profesor Asistente. C&aacute;tedra de Pediatr&iacute;a. Facultad de Ciencias M&eacute;dicas. Universidad Nacional de Asunci&oacute;n. Miembro del Tribunal de Recertificaci&oacute;n de la Sociedad Paraguaya de Pediatr&iacute;a.</font></p>      <p align="left"><font size="2" face="Verdana"><b>Solicitud de Sobretiros: </b>Prof. Dr. Ram&oacute;n Mir. Email: rmir1960@gmail.com.py</font></p>      <p align="left"><font size="2" face="Verdana">Art&iacute;culo recibido en Diciembre de 2009, aceptado para publicaci&oacute;n en Febrero de 2010.</font></p>      <p align="left">&nbsp;</p> <hr size="1" noshade>     ]]></body>
<body><![CDATA[<p align="left"><font size="2" face="Verdana"><b>RESUMEN</b></font></p>     <p align="left"><font size="2" face="Verdana">La ventilaci&oacute;n de alta frecuencia es una forma de ventilaci&oacute;n mec&aacute;nica que se utiliza en el reci&eacute;n nacido con insuficiencia respiratoria aguda; se caracteriza por la  utilizaci&oacute;n de peque&ntilde;os vol&uacute;menes corrientes, menor que el espacio muerto anat&oacute;mico, con frecuencia de ventilaci&oacute;n extremadamente alta. Su mecanismo de acci&oacute;n es diferente al de la ventilaci&oacute;n convencional, por lo cual es importante conocer sus caracter&iacute;sticas t&eacute;cnicas y operacionales antes  de su uso cl&iacute;nico. Las ventajas potenciales de esta t&eacute;cnica sobre la ventilaci&oacute;n mec&aacute;nica convencional incluyen su capacidad para realizar un adecuado intercambio gaseoso, en un pulm&oacute;n lesionado por barotrauma y volutrauma, usando presiones bajas en las v&iacute;as &aacute;reas proximales. En este art&iacute;culo se presentan algunos tipos de ventilaci&oacute;n de alta frecuencia, sobre todo la Ventilaci&oacute;n de Alta Frecuencia Oscilatoria, los posibles mecanismos de intercambio gaseoso que realiza este tipo de ventilaci&oacute;n, sus principales indicaciones y las estrategias de manejo cl&iacute;nico. </font></p>       <p align="left"><font size="2" face="Verdana"><b>Palabra clave: </b>Ventilaci&oacute;n de Alta frecuencia, reci&eacute;n nacido, insuficiencia respiratoria.</font></p>       <p align="left">&nbsp;</p>     <p align="left"><font size="2" face="Verdana"><b>ABSTRACT</b></font></p>     <p align="left"><font size="2" face="Verdana">High-frequency ventilation is a form of mechanical ventilation used in newborns with acute respiratory insufficiency and is characterized by the use of small volumes of flow, smaller than the anatomic space available, but at extremely high frequency. Its mechanism of action is different from that of conventional ventilation, for which reason it is important to recognize its technical and operational characteristics prior to clinical use. The advantages of this technique over conventional mechanical ventilation include the ability to achieve adequate gas exchange in a lung damaged by barotrauma or volutrauma by using low pressures in the proximal airways. In this article we present some types of high-frequency ventilation, concentrating on high frequency oscillatory ventilation, the possible mechanisms of gas exchange occurring in this type of ventilation, its primary indications, and some strategies for clinical management.</font></p>      <p align="left"><font size="2" face="Verdana"><b>Keywords: </b>High-frequency ventilation, newborns, respiratory insufficiency.</font></p>  <hr size="1" noshade>     <p align="justify">&nbsp;</p>     <p align="left"><font size="3" face="Verdana"><b>INTRODUCCI&Oacute;N</b></font></p>     <p align="left"><font size="2" face="Verdana">La ventilaci&oacute;n de alta frecuencia (VAF)  es una modalidad ventilatoria que se empez&oacute; a utilizar en forma experimental a fines de la d&eacute;cada de los a&ntilde;os ochenta, actualmente es utilizada en la mayor&iacute;a de las unidades neonatales  de EEUU, Europa y Am&eacute;rica para el tratamiento de RN con insuficiencia respiratoria.</font></p>      ]]></body>
<body><![CDATA[<p align="left"><font size="2" face="Verdana">El primer ventilador de alta frecuencia fue patentado por Jhon Emmerson en1959, &eacute;ste era un vibrador de la v&iacute;a &aacute;rea. Luego, Luckehmeiker en 1972, estudiando la impedancia tor&aacute;cica en perros apneicos, fortuitamente descubri&oacute; que pod&iacute;a mantener normocapnia con un peque&ntilde;o volumen de aire en las v&iacute;as &aacute;reas en los animales con frecuencia de 23 a 40 Hz (1Hz = 60 ciclos por minutos). Posteriormente, diversos investigadores demostraron que era posible una adecuada ventilaci&oacute;n alveolar con vol&uacute;menes corrientes menores que el espacio muerto anat&oacute;mico, con frecuencia supra fisiol&oacute;gica que caracteriza al ventilador de alta frecuencia (1). Sin embargo a pesar de numerosas publicaciones sobre todo de habla inglesa sobre el uso de la VAF, aun hay una controversia importante sobre c&oacute;mo y cu&aacute;ndo debe utilizarse VAF. En un extremo del espectro, est&aacute; un grupo de cl&iacute;nicos que la utilizan como una modalidad  primaria de ventilaci&oacute;n  para  reci&eacute;n nacidos que requieren apoyo ventilatorio, en tanto que en el otro extremo, se encuentran aquellos que la utilizan como una t&eacute;cnica de rescate  solo  cuando fracasa  la ventilaci&oacute;n convencional (2).</font></p>      <p align="left"><font size="2" face="Verdana">La ventilaci&oacute;n de alta frecuencia oscilatoria (VAFO) consigue un efectivo intercambio de anh&iacute;drido carb&oacute;nico (CO2) y oxigeno (O2) con menores valores de presi&oacute;n pico a nivel alveolar, m&iacute;nimas variaciones en las presiones y en los vol&uacute;menes de ventilaci&oacute;n, manteniendo los pulmones con un volumen relativamente constante, por encima de su capacidad residual funcional debido a la aplicaci&oacute;n de una presi&oacute;n media estable, minimizando los efectos volutrauma y el barotrauma (3).</font></p>      <p align="left"><font size="2" face="Verdana">Actualmente existen tres tipos generales de VAF:</font></p>      <p align="left"><font size="2" face="Verdana">Ventilaci&oacute;n de Alta Frecuencia  de Presi&oacute;n Positiva (VAFPP), la cual se realiza con ventilaci&oacute;n mec&aacute;nica convencional o modificada que opera a altas velocidades; ventilaci&oacute;n Jet de Alta Frecuencia (VAFJ), utiliza ventiladores que entregan chorros de gases a alta velocidad, dentro de las v&iacute;as a&eacute;reas, y Ventilaci&oacute;n Oscilatoria de Alta frecuencia (VAFO), la cual se realiza con un mecanismo que mueve el aire hacia delante y hacia atr&aacute;s en la v&iacute;a &aacute;rea proximal, produciendo un flujo m&iacute;nimo de gas.</font></p>      <p align="left"><font size="2" face="Verdana">En este momento solo un numero peque&ntilde;o de sistema de VAF esta aprobado para el uso cl&iacute;nico por la Administraci&oacute;n de Drogas y Alimentos de Estados Unidos, <b><i><a href="#1a08t1">(Tabla 1)</a></i></b>.</font></p>       <p align="center"><a name="1a08t1"></a></p>     <p align="left">&nbsp;</p>     <p align="center"><img src="../../../../../img/revistas/ped/v37n1/1a08t1.jpg"></p>       <p align="left"><font size="2" face="Verdana">La Unidad de Cuidados Intensivos Neonatales del Centro Materno Infantil cuenta con un Oscilador de alta Frecuencia desde hace aproximadamente dos a&ntilde;os, es el Sensor Medics 3100; en virtud a esto, nos propusimos presentar una actualizaci&oacute;n del  conocimiento de la Ventilaci&oacute;n  de Alta Frecuencia con &eacute;nfasis en  la VAFO</font></p>      <p align="left"><font size="2" face="Verdana">El ventilador de alta frecuencia oscilatoria (VAFO), proporciona un volumen de gas a trav&eacute;s de un pist&oacute;n o diafragma que comprime y luego libera la mezcla de gas en el circuito del respirador, movimiento del pist&oacute;n que determina un volumen corriente siempre menor que el espacio muerto anat&oacute;mico. La presi&oacute;n de la amplitud (que se mide como &Delta;P) que determina el volumen corriente entregado al paciente es ajustado aumentando o disminuyendo el movimiento de pist&oacute;n del diafragma y la presi&oacute;n media de la v&iacute;a &aacute;rea (PMVA), se controla variando el flujo basal (bias flow) y la apertura de la v&aacute;lvula espiratoria.</font></p>      ]]></body>
<body><![CDATA[<p align="left"><font size="2" face="Verdana">Una de sus caracter&iacute;sticas principales es que proporciona una espiraci&oacute;n activa, por la cual, la posibilidad de atrapamiento a&eacute;reo es m&iacute;nima o pr&aacute;cticamente nula (4).  Se utiliza una relaci&oacute;n  inspiraci&oacute;n/espiraci&oacute;n (I/E) 1:1 o mejor 1:2con frecuencia entre 6 a 20 Hz. La modalidad oscilatoria tiene la ventaja que tanto la PMVA, la amplitud, frecuencia y el tiempo inspiratorio, se puede ajustar directa e independientemente, facilitando el manejo para el operador.</font></p>      <p align="justify">&nbsp;</p>     <p align="left"><font size="3" face="Verdana"><b>MECANISMO DE TRANSPORTE DE GASES EN LA VAFO</b></font></p>      <p align="left"><font size="2" face="Verdana">La VAFO presenta cierta dificultad para comprender el mecanismo exacto de c&oacute;mo se efect&uacute;a el transporte de gas dentro del pulm&oacute;n y como se mantiene el intercambio gaseoso con vol&uacute;menes corrientes menores que el espacio muerto anat&oacute;mico.</font></p>      <p align="left"><font size="2" face="Verdana">En la VAFO la distribuci&oacute;n del gas es m&aacute;s uniforme y regular que la ventilaci&oacute;n mec&aacute;nica convencional (VMC) dependiendo m&aacute;s de la resistencia de las v&iacute;as a&eacute;reas principales y menos de la compliancia alveolar.</font></p>      <p align="left"><font size="2" face="Verdana">Adem&aacute;s, al utilizar vol&uacute;menes estables y menor variaci&oacute;n de presi&oacute;n en los ciclos de inflaci&oacute;n-deflaci&oacute;n, disminuye el riesgo de sobredistensi&oacute;n y el peligro de rotura (4,5).</font></p>      <p align="left"><font size="2" face="Verdana">En la VAFO el CO2 es removido fundamentalmente por una mezcla muy eficiente de gas en las v&iacute;as a&eacute;reas, la llamada difusi&oacute;n aumentada. La eliminaci&oacute;n  del CO2 es proporcional al producto de la frecuencia del ventilador de alta frecuencia y el volumen corriente al cuadrado (f x Vt2). De esto se deduce que durante la VAFO el aumento del volumen corriente o de la amplitud oscilatoria medida como Delta P (&Delta;P), tiene gran efecto con la eliminaci&oacute;n del CO2 (5,6).</font></p>      <p align="left"><font size="2" face="Verdana">Los posibles mecanismos que explican el transporte y el intercambio gaseoso de la VAF est&aacute;n muy bien descritos en el trabajo de Chang (7) y los principales mecanismos ser&iacute;an:</font></p>      <p align="left"><font size="2" face="Verdana">1. La ventilaci&oacute;n alveolar directa de las unidades alveolares m&aacute;s cercanas a las v&iacute;as a&eacute;reas principales.</font></p>      <p align="left"><font size="2" face="Verdana">2. El fen&oacute;meno de Pendelluft o mezcla interregional de gases. Debidos a la constante de tiempo que pueden existir entre las unidades alveolares vecinas, el llenado y el vaciado de la misma con asincronismo en el tiempo permite el paso de gas de las unidades lentas a las r&aacute;pidas y viceversa seg&uacute;n el ciclo respiratorio.</font></p>      ]]></body>
<body><![CDATA[<p align="left"><font size="2" face="Verdana">3. La dispersi&oacute;n convectiva axial. Los perfiles de velocidad en las v&iacute;as respiratorias son asim&eacute;tricas, acentu&aacute;ndose en las bifurcaciones bronquiales, presentando unos perfiles inspiratorios mas alterados que los inspiratorios. La presencia de turbulencia  produce una elevada mezcla de gases.</font></p>      <p align="left"><font size="2" face="Verdana">4. La ley de Taylor o de la dispersi&oacute;n aumentada. La dispersi&oacute;n de un gas es la resultante de la interacci&oacute;n de su perfil de velocidad axial y su difusi&oacute;n. A frecuencias altas se produce dentro de la columna de gas un flujo turbulento que con lleva una gran mezcla de gas entre el flujo central y el lateral.</font></p>      <p align="left"><font size="2" face="Verdana">5. La difusi&oacute;n molecular. Se trata del transporte de gas producida por la difusi&oacute;n de las mol&eacute;culas de O2 y CO2  a trav&eacute;s de la membrana alveolocapilar por efectos de los diferentes gradientes de presi&oacute;n.</font></p>      <p align="left"><font size="2" face="Verdana">6. Mezcla cardiaca. El gasto cardiaco favorece la mezcla de gas en la periferia del pulm&oacute;n.</font></p>       <p align="center"><a name="1a08f1"></a></p>     <p align="left">&nbsp;</p>     <p align="center"><img src="../../../../../img/revistas/ped/v37n1/1a08f1.jpg"></p>       <p align="justify">&nbsp;</p>     <p align="left"><font size="3" face="Verdana"><b>OXIGENACI&Oacute;N</b></font></p>     <p align="left"><font size="2" face="Verdana">La oxigenaci&oacute;n en la VAFO, es igual que en la VMC, depende de la Fracci&oacute;n inspiratoria de O2 (FiO2) y de la presi&oacute;n media de la v&iacute;a &aacute;rea (PMVA). La PMVA en la VAFO es tal vez el par&aacute;metro m&aacute;s importante; de su correcto uso depende en gran parte la oxigenaci&oacute;n del paciente. La PMVA optima que se debe alcanzar en la VAFO es aquella necesaria para superar la presi&oacute;n de cierre alveolar y que consiga reclutar el mayor numero posible de alveolos, aumentando as&iacute; al m&aacute;ximo la superficie pulmonar para realizar el intercambio gaseoso sin incrementar la resistencia vascular pulmonar o disminuir el gasto cardiaco, y esto debe ser mantenida  en forma constate evitando el desreclutamiento alveolar (8-10). LA PMVA es controlada directamente en el oscilador, manteni&eacute;ndose estable durante todo el ciclo respiratorio. Para medir el grado de expansi&oacute;n pulmonar se utiliza la radiograf&iacute;a de t&oacute;rax en forma seriada, cont&aacute;ndose el n&uacute;mero de espacios intercostales como una gu&iacute;a de expansi&oacute;n pulmonar. En general entre 8 y 9 espacios  intercostales con diafragma plano se considera una satisfactoria expansi&oacute;n pulmonar; m&aacute;s de 9 espacios intercostales, diafragma plano y silueta cardiaca estrecha, son sugerentes de una sobre expansi&oacute;n pulmonar.</font></p>      ]]></body>
<body><![CDATA[<p align="justify">&nbsp;</p>     <p align="left"><font size="3" face="Verdana"><b>MANEJO DE VENTILADOS DE ALTA FRECUENCIA</b></font></p>      <p align="left"><font size="2" face="Verdana">Los par&aacute;metros iniciales dependen de la patolog&iacute;a basal del reci&eacute;n nacido.</font></p>     <p align="left"><font size="2" face="Verdana">1. Fracci&oacute;n Inspiratoria de Ox&iacute;geno:   Igual que en la ventilaci&oacute;n convencional,  elevando &eacute;sta para  aumentar la oxigenaci&oacute;n y disminuyendo en caso contrario.</font></p>        <p align="left"><font size="2" face="Verdana">2. Presi&oacute;n Media en la V&iacute;a &Aacute;rea (PMVA): La PMVA es controlada directamente en el oscilador, manteni&eacute;ndose estable durante todo el ciclo respiratorio, se comienza con 1 a 2 cm H2O superior a la que ten&iacute;a en el  ventilador Convencional o la misma  para escapes a&eacute;reos. La PMVA en la VAFO es tal vez el par&aacute;metro m&aacute;s importante; de su correcto uso depende en gran parte la oxigenaci&oacute;n del paciente.</font></p>      <p align="left"><font size="2" face="Verdana">3. Frecuencia:   Se utiliza dentro de un rango entre 10 y 15 Hz (600 a 900 ciclos por minuto). En general cuando mayor es el peso del paciente, menor es la frecuencia utilizada; se sugiere en un reci&eacute;n nacido de muy bajo peso (&lt; de 1500 gr) iniciar con 15 Hz (900 ciclos por minutos) y en los de mayor peso con 10 Hz (600 ciclos por minuto).</font></p>      <p align="left"><font size="2" face="Verdana">4. Amplitud: Tambi&eacute;n denominada &Delta;P, por ser la diferencia entre la presi&oacute;n m&aacute;xima y la m&iacute;nima. El volumen proporcionado en cada ciclo respiratorio es directamente proporcional a la diferencia de la presi&oacute;n m&aacute;xima y la m&iacute;nima. A mayor amplitud oscilatoria medida en cm H2O, mayor el volumen corriente entregado al paciente y por ende mayor eliminaci&oacute;n de CO2. Se puede iniciar entre 30 a 40 cm de H2O.</font></p>      <p align="left"><font size="2" face="Verdana">5. Flujo: 20 litros por minuto</font></p>      <p align="left"><font size="2" face="Verdana">6. Tiempo inspiratorio: 33%</font></p>      <p align="justify">&nbsp;</p>     ]]></body>
<body><![CDATA[<p align="left"><font size="3" face="Verdana"><b>INDICACIONES DE LA VAFO</b></font></p>     <p align="left"><font size="2" face="Verdana">La indicaci&oacute;n actual de la Ventilaci&oacute;n de Alta Frecuencia Oscilatoria es utilizarlo como terapia de rescate cuando fracasa la VMC en patolog&iacute;as que cursan con atelectasia (4,11), escapes a&eacute;reos graves (12-15), hipertensi&oacute;n pulmonar persistente (16,17) y hernia diafragm&aacute;tica cong&eacute;nita (18,19).</font></p>      <p align="justify">&nbsp;</p>     <p align="left"><font size="3" face="Verdana"><b>RECOMENDACIONES GENERALES</b></font></p>     <p align="left"><font size="2" face="Verdana">1. Humidificaci&oacute;n. Debido  a la alta velocidad del flujo de gas se debe mantener una adecuada humidificaci&oacute;n  y temperatura de los gases inspirados (37&ordm;).</font></p>     <p align="left"><font size="2" face="Verdana">2.	Sedaci&oacute;n y relajaci&oacute;n. Es frecuente el uso de sedaci&oacute;n mientras el paciente permanece en la VAFO.</font></p>     <p align="left"><font size="2" face="Verdana">3.	Monitorizaci&oacute;n. La monitorizaci&oacute;n debe ser completa incluyendo cl&iacute;nica, laboratorial y radiol&oacute;gica en forma continua; controles gasom&eacute;tricos para reconocer el riesgo de hipocapnia que pudiera producirse, con el ulterior desarrollo de  secuelas neurol&oacute;gicas (20,21).</font></p>      <p align="justify">&nbsp;</p>     <p align="left"><font size="3" face="Verdana"><b>CONCLUSI&Oacute;N</b></font></p>     <p align="left"><font size="2" face="Verdana">La VAFO tiene actualmente indicaciones precisas, como son aquellos RN con  escapes a&eacute;reos y con insuficiencia respiratoria aguda renuentes a la ventilaci&oacute;n mec&aacute;nica convencional; sin embargo como cualquier otra t&eacute;cnica, presenta potenciales ventajas, pero tambi&eacute;n  potenciales riesgos si no es correctamente empleada; la VAFO solo debe ser aplicada en unidades con instalaciones que permitan una monitorizaci&oacute;n tanto cl&iacute;nica como bioqu&iacute;mica adecuadas. El personal m&eacute;dico y de enfermer&iacute;a  debe estar bien entrenado para lograr su uso en forma segura y eficaz en la practica cl&iacute;nica. Es indudable sin embargo que las Unidades de Cuidados  Intensivos Neonatales con  n&uacute;mero significativo de pacientes graves deber&iacute;an contar con un Ventilador de Alta Frecuencia como ayuda a la Ventilaci&oacute;n Mec&aacute;nica convencional, para aquellos Reci&eacute;n nacidos con insuficiencia respiratoria severa que requieran su uso.</font></p>      ]]></body>
<body><![CDATA[<p align="justify">&nbsp;</p>     <p align="left"><font size="3" face="Verdana"><b>REFERENCIAS</b></font></p>     <!-- ref --><p align="left"><font size="2" face="Verdana">1. Bancalari AM. Ventilaci&oacute;n de alta frecuencia en el reci&eacute;n nacido: un soporte respiratorio necesario. Rev Chl Pediatr. 2003;74(5):475-486.</font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=095533&pid=S1683-9803201000010000800001&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p align="left"><font size="2" face="Verdana">2. Kesler M, Durand D. Ventilaci&oacute;n de alta frecuencia neonatal: pasado, presente y futuro. Cl&iacute;nicas Perinatolog&iacute;as de Norteam&eacute;rica. 2001;3:557-583.</font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=095534&pid=S1683-9803201000010000800002&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p align="left"><font size="2" face="Verdana">3. Mammel MC. Ventilaci&oacute;n de Alta Frecuencia. En: Goldsmith JP, Karotkin EH, editores. Ventilaci&oacute;n Asistida Neonatal. 4ed. Bogot&aacute;: Colombia. Distribuna Editorial M&eacute;dica; 2005.p.267-291.</font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=095535&pid=S1683-9803201000010000800003&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p align="left"><font size="2" face="Verdana">4. Bancalari  E, Gerhardt T, Bancalari E. Gas trapping with high-frequency ventilation: jet versus oscillatory ventilation. J Pediatr. 1987;110:617-22.</font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=095536&pid=S1683-9803201000010000800004&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p align="left"><font size="2" face="Verdana">5. Grupo de trabajo sobre Patolog&iacute;a Respiratoria de la Sociedad Espa&ntilde;ola de Neonatolog&iacute;a. Recomendaciones  sobre Ventilaci&oacute;n de Alta Frecuencia en el reci&eacute;n nacido. An Esp  Pediatr. 2002;57(3):238-43</font>.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=095537&pid=S1683-9803201000010000800005&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p align="left"><font size="2" face="Verdana">6. Hatcher D, Watanabe II, Ashbury T, Vincent S, Fischer J, Froese A. Mechanical performance of clinically available, neonatal,  high frequency oscillatory-type ventilators. Crit Care Med. 1998;26:1081-88.</font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=095538&pid=S1683-9803201000010000800006&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p align="left"><font size="2" face="Verdana">7. Chang HK. Mechanisms of gas transport during ventilation by high-frequency oscillation. J Appl Physiol. 1984;56:553-63.</font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=095539&pid=S1683-9803201000010000800007&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p align="left"><font size="2" face="Verdana">8. McCulloch PR, Forker PG, Froese AB. Lung volume maintenance prevents lung injury during high frequency oscillatory ventilation. Am Rev Respir Dis. 1988;137:1185.</font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=095540&pid=S1683-9803201000010000800008&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p align="left"><font size="2" face="Verdana">9. HIFO Study Group. Randomized study of high-frequency oscillatory ventilation in infants with severe respiratory distress syndrome. J Pediatr. 1993;122:609-19.</font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=095541&pid=S1683-9803201000010000800009&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p align="left"><font size="2" face="Verdana">10. Morcillo F, Guti&eacute;rrez A, Izquierdo I. Ventilaci&oacute;n de alta frecuencia oscilatoria como estrategia de rescate en el reci&eacute;n nacido: estudio Multicentrico Espa&ntilde;ol. An Esp Pediatr. 1999;50:269-74.</font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=095542&pid=S1683-9803201000010000800010&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p align="left"><font size="2" face="Verdana">11. Thome U, Kossel H, Lipowsky G. Randomized comparison of high frequency ventilation with high-rate intermittent positive pressure ventilation in preterm infants with respiratory failure. J Pediatr. 1999;135:39-46.</font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=095543&pid=S1683-9803201000010000800011&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p align="left"><font size="2" face="Verdana">12. Moriette G, Paris-Llado J, Walti H. Prospective randomized multicenter comparison of high-frequency oscillator ventilation and conventional ventilation in preterm infants of less tan 30 weeks with respiratory distress syndrome. Pediatrics. 2001;107:363-72.</font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=095544&pid=S1683-9803201000010000800012&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p align="left"><font size="2" face="Verdana">13. Courtney SE, Durand DJ, Asselin JM. High-frequency oscillatory ventilation versus conventional mechanical ventilation for very low birth weight infants. N Engl J Med. 2002;347:643-52.</font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=095545&pid=S1683-9803201000010000800013&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p align="left"><font size="2" face="Verdana">14. The HIFI Study Group. High-frequency oscillatory ventilation compared with conventional mechanical ventilation in the treatment of respiratory failure in preterm infants. N Engl J Med. 1989;320:88-93.</font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=095546&pid=S1683-9803201000010000800014&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p align="left"><font size="2" face="Verdana">15. Johnson AH, Peacock JL, Greenough A, Marlow N. High-frequency oscillatory Ventilation for the prevention of cronic lung disease of prematurity. N Engl J Med. 2002;347:633-42.</font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=095547&pid=S1683-9803201000010000800015&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p align="left"><font size="2" face="Verdana">16. Clar K RH, Yoder BA, Sell MS. Prospective, randomized comparison of high-frequency oscillation and conventional in candidates for extracorporeal membrane oxygenation. J Pediatr. 1994;124:447-54.</font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=095548&pid=S1683-9803201000010000800016&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p align="left"><font size="2" face="Verdana">17. Bancalari A, Bustos R, Fasce J, Bello P, Campos L. Cifuentes L. Ventilaci&oacute;n de alta frecuencia en reci&eacute;n nacido con falla respiratoria aguda. Rev Chil Pediatr. 2002;73:667.</font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=095549&pid=S1683-9803201000010000800017&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p align="left"><font size="2" face="Verdana">18. Paranka MM, Clar K RH, Yoder BA, Sell MS. Predictors of failure of high-frequency oscillatory ventilation in terms infants with severe respiratory failure. Pediarics. 1995;95:400-4.</font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=095550&pid=S1683-9803201000010000800018&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p align="left"><font size="2" face="Verdana">19. Miguet D, Claris O, Lapillone A, Bakr a, Chapuiss JP, Salle BL. Preoperative     stabilization using high-frequency oscillatory ventilation in the management of congenital diaphragmatic hernia. Crit Care Med. 1994;22:S77.</font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=095551&pid=S1683-9803201000010000800019&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p align="left"><font size="2" face="Verdana">20. Morgan C, Dear PR, Newells SJ. Effect of changes in oscillatory amplitude PaCO(2) and PaO(2) during high frequency oscillatory ventilation. Arch Dis Child Fetal Neonatal Ed. 2000;82:F237-F42.</font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=095552&pid=S1683-9803201000010000800020&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><!-- ref --><p align="left"><font size="2" face="Verdana">21. Okumara A, Hayakawa F, Kato T, Itomi K, Maruyama K, Ishihara N, et-al. Hypocarbia in preterm infants with periventricular leukomacia: the relation between hypocarbia and mechanical ventilation. Pediatrics. 2001;107:469-75.</font>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;[&#160;<a href="javascript:void(0);" onclick="javascript: window.open('/scielo.php?script=sci_nlinks&ref=095553&pid=S1683-9803201000010000800021&lng=','','width=640,height=500,resizable=yes,scrollbars=1,menubar=yes,');">Links</a>&#160;]<!-- end-ref --><p><br /> </p>      ]]></body><back>
<ref-list>
<ref id="B1">
<label>1</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Bancalari]]></surname>
<given-names><![CDATA[AM]]></given-names>
</name>
</person-group>
<article-title xml:lang="es"><![CDATA[Ventilación de alta frecuencia en el recién nacido: un soporte respiratorio necesario]]></article-title>
<source><![CDATA[Rev Chl Pediatr.]]></source>
<year>2003</year>
<volume>74</volume>
<numero>5</numero>
<issue>5</issue>
<page-range>475-486</page-range></nlm-citation>
</ref>
<ref id="B2">
<label>2</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Kesler]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Durand]]></surname>
<given-names><![CDATA[D]]></given-names>
</name>
</person-group>
<article-title xml:lang="es"><![CDATA[Ventilación de alta frecuencia neonatal: pasado, presente y futuro]]></article-title>
<source><![CDATA[Clínicas Perinatologías de Norteamérica.]]></source>
<year>2001</year>
<volume>3</volume>
<page-range>557-583</page-range></nlm-citation>
</ref>
<ref id="B3">
<label>3</label><nlm-citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Mammel]]></surname>
<given-names><![CDATA[MC]]></given-names>
</name>
</person-group>
<article-title xml:lang="es"><![CDATA[Ventilación de Alta Frecuencia]]></article-title>
<person-group person-group-type="editor">
<name>
<surname><![CDATA[Goldsmith]]></surname>
<given-names><![CDATA[JP]]></given-names>
</name>
<name>
<surname><![CDATA[Karotkin]]></surname>
<given-names><![CDATA[EH]]></given-names>
</name>
</person-group>
<source><![CDATA[Ventilación Asistida Neonatal]]></source>
<year>2005</year>
<edition>4</edition>
<page-range>267-291</page-range><publisher-loc><![CDATA[Bogotá ]]></publisher-loc>
<publisher-name><![CDATA[Colombia. Distribuna Editorial Médica]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B4">
<label>4</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Bancalari]]></surname>
<given-names><![CDATA[E]]></given-names>
</name>
<name>
<surname><![CDATA[Gerhardt]]></surname>
<given-names><![CDATA[T]]></given-names>
</name>
<name>
<surname><![CDATA[Bancalari]]></surname>
<given-names><![CDATA[E]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Gas trapping with high-frequency ventilation: jet versus oscillatory ventilation]]></article-title>
<source><![CDATA[J Pediatr.]]></source>
<year>1987</year>
<volume>110</volume>
<page-range>617-22</page-range></nlm-citation>
</ref>
<ref id="B5">
<label>5</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Grupo]]></surname>
<given-names><![CDATA[de]]></given-names>
</name>
</person-group>
<article-title xml:lang="es"><![CDATA[Recomendaciones sobre Ventilación de Alta Frecuencia en el recién nacido]]></article-title>
<source><![CDATA[An Esp Pediatr.]]></source>
<year>2002</year>
<volume>57</volume>
<numero>3</numero>
<issue>3</issue>
<page-range>238-43</page-range></nlm-citation>
</ref>
<ref id="B6">
<label>6</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Hatcher]]></surname>
<given-names><![CDATA[D]]></given-names>
</name>
<name>
<surname><![CDATA[Watanabe]]></surname>
<given-names><![CDATA[II]]></given-names>
</name>
<name>
<surname><![CDATA[Ashbury]]></surname>
<given-names><![CDATA[T]]></given-names>
</name>
<name>
<surname><![CDATA[Vincent]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Fischer]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Froese]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Mechanical performance of clinically available, neonatal, high frequency oscillatory-type ventilators]]></article-title>
<source><![CDATA[Crit Care Med.]]></source>
<year>1998</year>
<volume>26</volume>
<page-range>1081-88</page-range></nlm-citation>
</ref>
<ref id="B7">
<label>7</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Chang]]></surname>
<given-names><![CDATA[HK]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Mechanisms of gas transport during ventilation by high-frequency oscillation]]></article-title>
<source><![CDATA[J Appl Physiol.]]></source>
<year>1984</year>
<volume>56</volume>
<page-range>553-63</page-range></nlm-citation>
</ref>
<ref id="B8">
<label>8</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[McCulloch]]></surname>
<given-names><![CDATA[PR]]></given-names>
</name>
<name>
<surname><![CDATA[Forker]]></surname>
<given-names><![CDATA[PG]]></given-names>
</name>
<name>
<surname><![CDATA[Froese]]></surname>
<given-names><![CDATA[AB]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Lung volume maintenance prevents lung injury during high frequency oscillatory ventilation]]></article-title>
<source><![CDATA[Am Rev Respir Dis.]]></source>
<year>1988</year>
<volume>137</volume>
<page-range>1185</page-range></nlm-citation>
</ref>
<ref id="B9">
<label>9</label><nlm-citation citation-type="journal">
<collab>HIFO Study Group</collab>
<article-title xml:lang="en"><![CDATA[Randomized study of high-frequency oscillatory ventilation in infants with severe respiratory distress syndrome]]></article-title>
<source><![CDATA[J Pediatr.]]></source>
<year>1993</year>
<volume>122</volume>
<page-range>609-19</page-range></nlm-citation>
</ref>
<ref id="B10">
<label>10</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Morcillo]]></surname>
<given-names><![CDATA[F]]></given-names>
</name>
<name>
<surname><![CDATA[Gutiérrez]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Izquierdo]]></surname>
<given-names><![CDATA[I]]></given-names>
</name>
</person-group>
<article-title xml:lang="es"><![CDATA[Ventilación de alta frecuencia oscilatoria como estrategia de rescate en el recién nacido: estudio Multicentrico Español]]></article-title>
<source><![CDATA[An Esp Pediatr.]]></source>
<year>1999</year>
<volume>50</volume>
<page-range>269-74</page-range></nlm-citation>
</ref>
<ref id="B11">
<label>11</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Thome]]></surname>
<given-names><![CDATA[U]]></given-names>
</name>
<name>
<surname><![CDATA[Kossel]]></surname>
<given-names><![CDATA[H]]></given-names>
</name>
<name>
<surname><![CDATA[Lipowsky]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Randomized comparison of high frequency ventilation with high-rate intermittent positive pressure ventilation in preterm infants with respiratory failure]]></article-title>
<source><![CDATA[J Pediatr.]]></source>
<year>1999</year>
<volume>135</volume>
<page-range>39-46</page-range></nlm-citation>
</ref>
<ref id="B12">
<label>12</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Moriette]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
<name>
<surname><![CDATA[Paris-Llado]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Walti]]></surname>
<given-names><![CDATA[H]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Prospective randomized multicenter comparison of high-frequency oscillator ventilation and conventional ventilation in preterm infants of less tan 30 weeks with respiratory distress syndrome]]></article-title>
<source><![CDATA[Pediatrics.]]></source>
<year>2001</year>
<volume>107</volume>
<page-range>363-72</page-range></nlm-citation>
</ref>
<ref id="B13">
<label>13</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Courtney]]></surname>
<given-names><![CDATA[SE]]></given-names>
</name>
<name>
<surname><![CDATA[Durand]]></surname>
<given-names><![CDATA[DJ]]></given-names>
</name>
<name>
<surname><![CDATA[Asselin]]></surname>
<given-names><![CDATA[JM]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[High-frequency oscillatory ventilation versus conventional mechanical ventilation for very low birth weight infants]]></article-title>
<source><![CDATA[N Engl J Med.]]></source>
<year>2002</year>
<volume>347</volume>
<page-range>643-52</page-range></nlm-citation>
</ref>
<ref id="B14">
<label>14</label><nlm-citation citation-type="journal">
<collab>The HIFI Study Group</collab>
<article-title xml:lang="en"><![CDATA[High-frequency oscillatory ventilation compared with conventional mechanical ventilation in the treatment of respiratory failure in preterm infants]]></article-title>
<source><![CDATA[N Engl J Med.]]></source>
<year>1989</year>
<volume>320</volume>
<page-range>88-93</page-range></nlm-citation>
</ref>
<ref id="B15">
<label>15</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Johnson]]></surname>
<given-names><![CDATA[AH]]></given-names>
</name>
<name>
<surname><![CDATA[Peacock]]></surname>
<given-names><![CDATA[JL]]></given-names>
</name>
<name>
<surname><![CDATA[Greenough]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Marlow]]></surname>
<given-names><![CDATA[N]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[High-frequency oscillatory Ventilation for the prevention of cronic lung disease of prematurity]]></article-title>
<source><![CDATA[N Engl J Med.]]></source>
<year>2002</year>
<volume>347</volume>
<page-range>633-42</page-range></nlm-citation>
</ref>
<ref id="B16">
<label>16</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Clar]]></surname>
<given-names><![CDATA[K RH]]></given-names>
</name>
<name>
<surname><![CDATA[Yoder]]></surname>
<given-names><![CDATA[BA]]></given-names>
</name>
<name>
<surname><![CDATA[Sell]]></surname>
<given-names><![CDATA[MS]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Prospective, randomized comparison of high-frequency oscillation and conventional in candidates for extracorporeal membrane oxygenation]]></article-title>
<source><![CDATA[J Pediatr.]]></source>
<year>1994</year>
<volume>124</volume>
<page-range>447-54</page-range></nlm-citation>
</ref>
<ref id="B17">
<label>17</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Bancalari]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Bustos]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
<name>
<surname><![CDATA[Fasce]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Bello]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
<name>
<surname><![CDATA[Campos]]></surname>
<given-names><![CDATA[L.]]></given-names>
</name>
</person-group>
<article-title xml:lang="es"><![CDATA[Ventilación de alta frecuencia en recién nacido con falla respiratoria aguda]]></article-title>
<source><![CDATA[Rev Chil Pediatr.]]></source>
<year>2002</year>
<volume>73</volume>
<page-range>667</page-range></nlm-citation>
</ref>
<ref id="B18">
<label>18</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Paranka]]></surname>
<given-names><![CDATA[MM]]></given-names>
</name>
<name>
<surname><![CDATA[Clar]]></surname>
<given-names><![CDATA[K RH]]></given-names>
</name>
<name>
<surname><![CDATA[Yoder]]></surname>
<given-names><![CDATA[BA]]></given-names>
</name>
<name>
<surname><![CDATA[Sell]]></surname>
<given-names><![CDATA[MS]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Predictors of failure of high-frequency oscillatory ventilation in terms infants with severe respiratory failure]]></article-title>
<source><![CDATA[Pediarics.]]></source>
<year>1995</year>
<volume>95</volume>
<page-range>400-4</page-range></nlm-citation>
</ref>
<ref id="B19">
<label>19</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Miguet]]></surname>
<given-names><![CDATA[D]]></given-names>
</name>
<name>
<surname><![CDATA[Claris]]></surname>
<given-names><![CDATA[O]]></given-names>
</name>
<name>
<surname><![CDATA[Lapillone]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Bakr]]></surname>
<given-names><![CDATA[a]]></given-names>
</name>
<name>
<surname><![CDATA[Chapuiss]]></surname>
<given-names><![CDATA[JP]]></given-names>
</name>
<name>
<surname><![CDATA[Salle]]></surname>
<given-names><![CDATA[BL]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Preoperative stabilization using high-frequency oscillatory ventilation in the management of congenital diaphragmatic hernia]]></article-title>
<source><![CDATA[Crit Care Med.]]></source>
<year>1994</year>
<volume>22</volume>
<page-range>S77</page-range></nlm-citation>
</ref>
<ref id="B20">
<label>20</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Morgan]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
<name>
<surname><![CDATA[Dear]]></surname>
<given-names><![CDATA[PR]]></given-names>
</name>
<name>
<surname><![CDATA[Newells]]></surname>
<given-names><![CDATA[SJ]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Effect of changes in oscillatory amplitude PaCO(2) and PaO(2) during high frequency oscillatory ventilation]]></article-title>
<source><![CDATA[Arch Dis Child Fetal Neonatal Ed.]]></source>
<year>2000</year>
<volume>82</volume>
<page-range>F237-F42</page-range></nlm-citation>
</ref>
<ref id="B21">
<label>21</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Okumara]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Hayakawa]]></surname>
<given-names><![CDATA[F]]></given-names>
</name>
<name>
<surname><![CDATA[Kato]]></surname>
<given-names><![CDATA[T]]></given-names>
</name>
<name>
<surname><![CDATA[Itomi]]></surname>
<given-names><![CDATA[K]]></given-names>
</name>
<name>
<surname><![CDATA[Maruyama]]></surname>
<given-names><![CDATA[K]]></given-names>
</name>
<name>
<surname><![CDATA[Ishihara]]></surname>
<given-names><![CDATA[N,]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Hypocarbia in preterm infants with periventricular leukomacia: the relation between hypocarbia and mechanical ventilation]]></article-title>
<source><![CDATA[Pediatrics.]]></source>
<year>2001</year>
<volume>107</volume>
<page-range>469-75</page-range></nlm-citation>
</ref>
</ref-list>
</back>
</article>
