Scientific Electronic Library Online

 
vol.4 no.1Frecuencia alélica de apolipoproteina E en una población aborigenCorrelación entre las concentraciones séricas de apolipoproteína B y colesterol LDL en una muestra poblacional. Utilidad de la apolipoproteina B para valorar riesgo aterogénico  índice de autoresíndice de assuntospesquisa de artigos
Home Pagelista alfabética de periódicos  

Memorias del Instituto de Investigaciones en Ciencias de la Salud
ISSN 1812-9528 versão on-line

 
 
Como citar este artigo
 
 

Resumo

RODRIGUEZ, E, RAMIREZ, C, MOLINA, L et al. Evaluación externa de la calidad en la determinación de ácido úrico en un grupo de laboratorios clínicos de Mérida-Venezuela. Mem. Inst. Investig. Cienc. Salud, jun. 2006, vol.4, no.1, p.28-33. ISSN 1812-9528.

The programs of external quality assessment began in Venezuela on 1977 for glucose, urea and creatinine, showing carelessness in the quality of the analyses. Being important to survey the analytical performance in this area, this work was developed to evaluate the performance in uric acid determinations of a group of clinical laboratories from Mérida (Venezuela). Commercial control sera: Normal Control (CN: 5.1 mg/dL) and Abnormal Control (CA: 9.7 mg/dL) were randomly distributed every fifteen days to 14 clinical laboratories (both public and private). They were asked to perform three determinations on each control serum, using the uricase-peroxidase method. The intra-laboratory and inter-laboratory precisions were determined through the variation coefficient (CV) and the intra-and inter-assay accuracies were determined through the percent relative deviation (DRP) of the individual value (intra-assay) or the mean of the three determinations (inter-assay) in relation to the consensus value. The lowest imprecision was obtained when performing the second determination of CA (CV=9.75%), 42.9% of the laboratories showed intra-laboratory precision (CV lower or equal than 5%) and inter-assay accuracy (DRP lower or equal than 15%) on both control sera. Further, 50% of the laboratories were accurate in the three CA determinations whereas 57.14% were accurate determining CN. The best performance was obtained in the second determination of CN and CA: 78.57% of the laboratories exhibited acceptable DRP values for CN and 85.71% for CA. We concluded that it is necessary to improve the reliability of the uric acid determination in these laboratories.

Palavras-chave: Consensus value; reliability; accuracy; precision.

        · resumo em espanhol     · texto em espanhol     · pdf em espanhol


 

© 2014  IICS

Río de la Plata y Lagerenza
Código Postal 2511 Asunción, Paraguay
Tel.: 595-21-421312 / 422069



editorial@iics.una.py